Examples: SYSTem:COMM:NET:GATE 192.168.10.2
NET:GATE 192.168.10.2
Query Syntax: [SYSTem][:COMMunicate]:NETwork:GATE?
Returned Parameters: <string>
Related Commands: NET:MAC, NET: ADDR, NET:SUBN, NET:PORT, NET:HOST,
NET:DHCP
4.3.12.6 NET:SUBN (Optional Ethernet only)
This command sets the subnet IP Mask address of the Ethernet module of the power supply.
The factory subnet mask setting is 255.255.255.0.
Command Syntax: [SYSTem][:COMMunicate]:NETwork:SUBNet<string>
Parameters: IP mask address is represented with 4 bytes each having a range of 0-255
separated by dots
Examples: SYSTem:COMM:NET:SUBNet 255.255.255.128
NET: SUBNet 255.255.255.128
Query Syntax: [SYSTem][:COMMunicate]:NETwork:SUBNet?
Returned Parameters: <string>
Related Commands: NET:MAC, NET: ADDR, NET:GATE, NET:PORT, NET:HOST,
NET:DHCP
4.3.12.7 NET:PORT (Optional Ethernet only)
This command sets the Socket (Port) of the Ethernet module of the power supply.
The factory default port setting is 50505. The factory recommends port values greater than 49151
to avoid conflicts with registered Ethernet port functions.
Command Syntax: [SYSTem][:COMMunicate]:NETwork:PORT <integer >
Parameters: 16-bit socket number (1 to 65,535)
Examples: SYSTem:COMM:NET: PORT 50505
NET: PORT 50505
Query Syntax: [SYSTem][:COMMunicate]:NETwork:PORT?
Returned Parameters: <integer>