Output current: ±0.2%,
+10V Ref: ±.50%.
Digital programming accuracy of full scale:
Voltage set point: ±0.075%,
Current set point: ±0.075%,
Over voltage trip set point: ±0.075%,
Over current trip set point: ±0.075%.
Digital readback accuracy of full scale:
Output voltage: ±0.2%,
Output current: ±0.2%.
Digital control inputs and outputs limits:
Input voltage: 0 to 5 Vdc, 10K input impedance;
Output voltages: 0 to 5 Vdc, 5 mA drive capacity per line;
5 V supply: 25 mA.
User interface connectors, see figure 1.1 and Tables 1.5, 1.6, 1.7, 1.8, and 1.9 for details:
JS1: 37 pin D-Subminiature, female;
JS2: 2 terminal 6-32 screw connector;
JS3: 9 pin D-Subminiature, female.
JS4: optional 24 pin IEEE-488, female.
JS5: optional 8 pin RJ45, female.
RS232 interface:
Baud Rate: 19200 Baud,
Data Size: 8-bit,
Parity: None,
Stop bits: 1.
Optional Ethernet Interface:
IP address: 169.254.x.x
Subnet Mask: 255.255.0.0
Default Getaway: 0.0.0.0
DNS Server: 0.0.0.0
Size and Weight: see figure 1.2 and Table 1.4 for details.
Agency Approvals:
CE-marked units meet the following standards:
EN61010-1:2001-02 Safety Requirements for Electrical Equipment for