0.04 %/EC of maximum output voltage,
0.06 %/EC of maximum output current.
Isolation:
User inputs and outputs: referenced to earth ground,
Maximum input voltage to ground: ±2500 Vac,
Maximum output voltage to ground: ±1000 Vdc.
Power Factor: greater than 92% at maximum power, 3φ inputs,
greater than 70% at maximum power for 1φ inputs.
Ambient Temperature: 0 to 50EC.
Storage Temperature: -25 to +85EC.
Remote sense limits: 3% maximum voltage drop from output terminals to load.
Remote analog programming limits:
Voltage set point: 0 to 10.0 Vdc for 0 to 100% output,
Current set point: 0 to 10.0 Vdc for 0 to 100% output,
Over voltage trip set point: 0 to 10.0 Vdc for 0 to 110% output,
Over current trip set point: 0 to 10.0 Vdc for 0 to 110% output,
Modulation: 0 to 10 Vdc.
Remote analog input impedance: 10K for all inputs.
Remote analog programming accuracy of full scale:
Voltage set point: ±0.075%,
Current set point: ±0.075%,
Over voltage trip set point: ±0.075%,
Over current trip set point: ±0.075%.
Analog monitoring and reference:
Output voltage: 0 to 10.0 Vdc, 5 mA,
Output current: 0 to 10.0 Vdc, 5 mA,
+10V Ref: 10.0 Vdc, 5 mA,
Analog output impedances:
Voltage output monitoring: 100 ohm,
Current output monitoring: 100 ohm,
+10V Ref: 1 ohm.
Analog monitoring accuracy of full scale:
Output voltage: ±0.2%,
6