Examples: CALibrate:STOP
CAL:STOP
Query Syntax: None
Related Commands: None
4.3.10 Configure Subsystem
The Configure Subsystem sets and returns the configuration of the power supply.
4.3.10.1 REM:SENS
This command sets voltage sensing to remote or local mode. Remote sensing, as described in
Section 3.3, improves the degradation of regulation which will occur at the load when the voltage
drop in the connecting wires is appreciable. The local sense mode monitors the voltage at the
output terminals of the power supply.
The query command, REM:SENS?, returns the state of the sense lines.
Command Syntax: [CONFigure]:REMote:SENSe <bool>
Parameters: 0 | OFF | 1 | ON
Examples: CONF:REM:SENS ON
REMOTE:SENSE 0
Query Syntax: [CONFigure]:REMote:SENSe?
Returned Parameters: 0 | 1
Related Commands: None
4.3.10.2 CONT:INT
This command enables or disables the front panel switches and keys for start, stop, arm, and clear.
The query command, CONT:INT?, returns the status of internal control.
Command Syntax: [CONFigure]:CONTrol:INTernal <bool>
Parameters: 0 | OFF | 1 | ON
Examples: CONF:CONT:INT ON
CONT:INT 0
Query Syntax: [CONFigure]:CONTrol:INTernal?
63