Command Syntax: OUTPut:START <>
Examples: OUTP:START
OUTPUT:START
Query Syntax: none
Related Commands: *RST, OUTP:STOP, OUTP:ARM, PER
4.3.5.4 OUTP:STOP
This command opens the power supply’s input contactor and terminates operation in either
normal mode or auto sequence mode.
Command Syntax: OUTPut:STOP <>
Examples: OUTP:STOP
OUTPUT:STOP
Query Syntax: none
Related Commands: *RST, OUTP:START, OUTP:ARM, PER
4.3.5.5 OUTP:PROT:CLE
This command clears the alarm latches. There are seven alarm latches, namely: interlock,
program line, phase balance, thermal, over voltage trip, over current trip, and fuse. When a fault is
detected, the power supply is rendered to an alarm state. The power supply cannot be restarted
until the protection condition is cleared and the latch is reset.
Command Syntax: OUTPut:PROTection:CLEar <>
Examples: OUTP:PROT:CLE
OUTPUT:PROTECTION:CLEAR
Query Syntax: none
Related Commands: *RST, *RCL, *SAV
4.3.6 Abort Subsystem
This subsystem cancels any trigger actions presently in process. Any pending trigger levels are
reset to their immediate values. ABOR also resets the WTG bit in the Operation Register. If
58