buna-N reinforced nylon fabric (NR). The valve(s) shall have a flow control and internal manual bleed located under the micro-powered actuator
solenoid and allow for manual operation by turning the manual bleed handle to the left to open and to the right to close. The valve(s) shall provide
easy access for removing all parts from the top of the valve without disturbing normal valve installation.
b2. Micro-powered solenoid actuator only
Micro-powered solenoid actuator (LEMA 1600HE) shall be with the correct adapter to be mounted on any valve (please refer to the back page for
detail). The controller shall communicate to the micro-powered solenoid actuator via two-way digital control pulses.
c. LEIT Key – The controller shall use one LEIT Key (powered by a 9-volt battery) to provide access and to activate the controller’s LCD screen.
3.1.3 Controller Accessories Descriptions
a. Stainless steel enclosure
For added protection the controller shall have the option to add a (304) Stainless Steel vandal resistant enclosure with strip perforations on top, allowing
light to enter the controller, plus a lockable hinged door. (Lock included)
b. Sensor adapter – The controller or the micro-powered solenoid actuator shall have an option to connect to all types of switch type sensors via the SKIT
sensor adapter. The SKIT adapter shall be used as an interface between the controller and a compatible rain, moisture or freeze protection sensor.
c. MV/P adapter: The controller shall have an option to switch on/off an AC or DC circuit via the RKIT relay interface adapter.The RKIT adapter shall be used
as an interface between the controller and AC switch device.
d. Swivel fittings – Micro-powered solenoid actuator with globe valve shall be used with swivel fittings as a union and shall allow, in case of repair, that the
valve may be brought to the surface to be serviced without removing the irrigation box or cutting the pipe. The swivel fitting shall be constructed of
injected molded polypropylene, UV resistant. The swivel fitting shall feature high impact strength plastic and be highly chemical resistant. The male thread
of the swivel fittings shall be attached to both sides of the valve. The female thread side of the swivel fitting shall have a large swivel 1", 11/2" or 2"
(FNPT) with encapsulated Nitric rubber “O” ring in such a manner that allows quick and easy tightening to a PVC male adapter without tools and teflon
tape. The swivel fitting operating pressure shall not exceed 150 PSI.
PPaarrtt 44 SSuubbmmiittttaallss
The following items shall be submitted by filling in the appropriate number of units and submitting (QTY) with a copy of catalog and instruction manual.
a. The LEIT X powered irrigation controller shall be _____ each of the LEIT [X10] 4 ten station, [X12] twelve station, [X16] sixteen station, [X20] twenty
station, [X24] 24 station and [x28] twenty-eight station
OR
The LEIT XR powered irrigation controller shall be _____ each of the LEIT [XR04] four station, [XR06] six station, [XR08] eight station, [XR10] ten station,
[XR12] twelve station, [XR16] 16 station, [XR20] twenty station, [XR24] twenty-four station and [XR28] twenty-eight station
OR
The LEIT XRC powered irrigation controller with 2-way radio shall be _____ each of the LEIT [XRC04] four station, [XRC06] six station, [XRC08] eight
station, [XRC10] ten station, [XRC12] twelve station, [XRC16] 16 station, [XRC20] twenty station, [XRC24] twenty-four station and [XRC28] twenty-eight
station
b. The two-way data communication micro-powered solenoid actuator or valve shall be _____ each of:
1. Long distance micro-powered solenoid actuator and valve model [160HE-075] for 3/4", [160HE-100] for 1", [160HE-150] for 11/2" and [160HE-200]
for 2" actuator and valve(s) or equal.
2. If other than the above are selected, use the two-way data communication micro-powered solenoid actuator model LEMA 1600HE with the correct
adapter to match the valve in use (See back page for adapter compatibility).
c. The light powered irrigation controller shall require ____ each of LEIT Key to enter the system. The same key can be used with any LEIT controller.
d. Each irrigation controller shall require one mounting column and shall have ____ each of MCOL XS (35") short or MCOLXL (50") long mounting column
and column kit.
e. The controller shall require if applicable _____ each of the RKIT 8810S relay interface adapter, used as an interface between the controller and pump
switch.
f. The LEIT XRC irrigation controller with LEIT Link 2-way radio can operate via a radio frequency of 900-928 MHz using a 2-way radio and shall be required
____ each of the radio handset. LEIT Link Multi-Pro can communicate with up to 99 controllers or LEIT Link Master can operate with up to 99 groups of
controllers, each with up to 99 controllers.
g. The 1", 1 1⁄2" and 2" valves shall use a male swivel adapter as a union with 2 per valve for 1" ____ model 23-003 for 11⁄2" ____ model 23-152 and for
2" ____ model 23-202
h. The light powered irrigation controller shall also require ____ each of the ENCL X (if a stainless steel enclosure is required for extra protection against
vandalism and theft).
PPaarrtt 55 IInnssttaallllaattiioonn
5.1 Electrical Circuits
Install irrigation wires at least six inches below finish grade and lay to the side and below main line.
a. Control wire for LEIT operated valve with LEMA 1600HE shall be NFPA 70 copper conductor, 14-gauge [1.8 mm] irrigation wire, type UF, shall be used for
station wire with runs up to 4500' (1360 m). NFPA 70 copper conductor 12-gauge [1.6 mm] irrigation wire, type UF, shall be used for station wire with
runs up to 7500' (2270 m).
b. Electrical splices shall be waterproof and shall be located in valve box.
c. An expansion curl shall be provided so that in case of repairs the valve may be brought to the surface to be serviced without disconnecting the control
wire.
Comentarios a estos manuales